Liner Hangers

Noncemented liner hanger PHN1

The PHN1 liner hanger is used to RIH and hang non-cemented liners. It is manufactured in
2 modifications, differed by the type of internal space shut-off:

  • by throttling valve, which gets closed by increased circulation rate;
  • by pumping of cementing plug or activation ball, that land into a landing seat located at
    the bottom of hanger mandrel.
  • PHN1 is equipped with UIF (unit of isolation of filters), allowing to circulate through the
    liner shoe.

PHN1 hanger consists of 4 functionally independent parts:

  • anchor to hang the liner assembly in the casing string;
  • hydro-mechanical packer to isolate annular space;
  • hydraulic release mechanism that allows to RIH liner assembly, circulate, activate
    anchor/packer by hydraulic pressure and, then, disconnect the drill string from PHN1
    by applying hydraulic pressure.
  • mechanical release to back up a hydraulic disconnection mechanism.

Design of PHN1 is practically identical to that of PHCZ1, except that at the end of tool
mandrel, there installed a landing seat or a throttling shut-off valve, instead of hollow
cement plug, and mandrel has circulation ports.

PARAMETER DESCRIPTION VALUE
PHN1.102/146;
PHN1.102/146-01
PHN1.114/168;
PHN1.114/168-01
PHN1.114/168-UIF
Liner nominal OD, mm 102 114
Casing nominal OD, mm 146 168
Maximum anchoring casing ID, mm 135 154
Maximum tool OD (at centralizer), mm 120 (122) 138 (141)
Drift ID (after activation), mm 89 99
Values of differential activation pressures1, MPa
– anchor
– packer
– hydraulic disconnection device
16,5
16,5
20
16
16
20
Maximum differential pressure on packer, MPa 15
Maximum operating temperature2, °C 100
Maximum axial tensile load on disconnection device3, kN 600 700
Connecting threads4:
– top GOST 28487 (GOST R 50864)
– bottom GOST 632-80
– pup-joint GOST 633
Z-86
ОТТМ 102
Z-102
ОТТМ 114
Z-102
ОТТМ 114
60
Length in operating position, mm 3340 3331 3563
Weight in operating position, kg 119 (125) 160 (163) 170

 

1 The values are given for all shear bolts installed.

2 For reference only! – depends on operating conditions for rubber parts in a well.

3 Calculated value when stresses reach tensile yield of the material.

PARAMETER DESCRIPTION VALUE
PHN1.127/178;
PHN1.127/178-01
PHN1.127/178-114;
PHN1.127/178-114-01
PHN1.127/178-UIF PHN1. 127/178-114-UIF
Liner nominal OD, mm 127 114 127 114
Casing nominal OD, mm 178 178 178 178
Maximum anchoring casing ID, mm 166
Maximum tool OD (at centralizer), mm 149 (152)
Drift ID (after activation), mm 111 99 111 99
Values of differential activation pressures1, MPa
– anchor
– packer
– hydraulic disconnection device
16
16
20
Maximum differential pressure on packer, MPa 15
Maximum operating temperature2, °C 100
Maximum axial tensile load on disconnection device3, kN 800 700 800 700
Connecting threads4:
– top GOST 28487 (GOST R 50864)
– bottom GOST 632-80
– pup-joint GOST 633
3-102
ОТТМ 127
3-102
ОТТМ 114
З-102
ОТТМ
127
60
З-102
ОТТМ
114
60
Length in operating position, mm 3395 3375 3678 3678
Weight in operating position, kg 182
(185)
182
(185)
190 182

 

1 The values are given for all shear bolts installed.

2 For reference only! – depends on operating conditions for rubber parts in a well.

3 Calculated value when stresses reach tensile yield of the material.